OpenAI 与生物技术公司 Ligo 合作推出 BioBasicsBench,包含 100 项常规湿实验室任务,用于评估 AI agent 解读原始实验数据、识别错误并判断证据是否足以支撑结论的能力。在允许更多推理的 xhigh 设置下,GPT-6 Astra 平均获得 66.7% 的可用分数,GPT-5.6 Sol 为 43.8%。该基准填补了现有以论文图表为主的评测对实验模糊性与排障能力的覆盖不足。
OpenAI, working with biotech company Ligo, introduced BioBasicsBench, a 100-task benchmark that measures how well AI agents interpret raw experimental data, detect errors and recognize when evidence cannot support a conclusion. At the 'xhigh' setting, GPT-6 Astra averaged 66.7% of available credit versus 43.8% for GPT-5.6 Sol. The benchmark targets the ambiguity and troubleshooting of routine wet-lab work that paper-chart benchmarks tend to miss.
推出 BioBasicsBench,这是一个基准测试,用于衡量 AI 智能体在 100 项常规湿实验室任务中解读原始实验数据的能力。
Introducing BioBasicsBench, a benchmark measuring how well AI agents interpret raw experimental data across 100 routine wet-lab tasks.
我们的使命是确保通用人工智能造福全人类。作为这一使命的一部分,我们希望帮助科学家加速生物学研究——从理解疾病到开发新疗法。要让 AI 智能体作出贡献,它们需要可靠地解读科学家每天在湿实验室中处理的实验证据,也就是用生物样本开展实验的地方。日常湿实验室工作涉及失败的实验、模糊的图像和相互矛盾的观察结果。现有基准测试围绕为科学论文挑选的图表和图像构建,可能忽略这种模糊性以及所需的故障排查。因此,我们推出 BioBasicsBench,这是与专注于酶设计的生物技术公司 Ligo 共同开发的新基准测试,用于衡量智能体处理常规湿实验室分析的能力。
Our mission is to ensure that artificial general intelligence benefits all of humanity. As part of that mission, we want to help scientists accelerate biological research—from understanding disease to developing new treatments. For AI agents to contribute, they need to reliably interpret the experimental evidence scientists work with every day in wet labs, where they run experiments with biological samples. Everyday wet-lab work involves failed experiments, ambiguous images and conflicting observations. Existing benchmarks are built around charts and images selected for scientific papers may miss this ambiguity and the troubleshooting it requires. That’s why we’re introducing BioBasicsBench, a new benchmark developed with Ligo, a biotech company focused on enzyme design, to measure how well agents handle routine wet-lab analysis.
该基准测试的 100 项任务检验智能体能否解读原始实验数据、识别错误,并判断证据何时无法支持某一结论。正确完成这些任务很重要,因为误读图像或忽视用于检查实验结果的对照所存在的问题,可能导致科学家得出错误结论,并把时间花在无助于回答其问题的实验上。
The benchmark’s 100 tasks test whether agents can interpret raw experimental data, identify errors, and recognize when the evidence cannot support a conclusion. Getting these tasks right matters because misreading an image or overlooking a problem with the controls used to check an experiment’s results can lead scientists to draw the wrong conclusion and spend time on experiments that won’t help answer their question.
在允许每项任务进行更多推理的“xhigh”设置下,GPT‑6 Astra 平均获得可用分数的 66.7%,而 GPT‑5.6 Sol 为 43.8%。结果表明常规实验室分析取得了进展,但在解读图像、检查对照和应用实验背景方面仍有进一步改进的空间。
At the ‘xhigh’ setting, which allows more reasoning per task, GPT‑6 Astra earned an average of 66.7% of the available credit, compared with 43.8% for GPT‑5.6 Sol. The results show progress on routine lab analysis, with room for further improvements in interpreting images, checking controls and applying experimental context.
BioBasicsBench 使用原始实验证据,从凝胶图像和菌落平板到显微镜和仪器读数。
BioBasicsBench uses raw experimental evidence, from gel images and colony plates to microscopy and instrument readouts.
BioBasicsBench 包含 100 项任务,覆盖常规湿实验室工作的五个领域:蛋白质方法、成像与细胞术、定量与检测、核酸方法以及分子克隆。任务范围从简单请求(例如读取凝胶中 DNA 样本的分子量)到详细的检测分析,但都涉及湿实验室科学家应当能够可靠完成的常规工作。
BioBasicsBench has 100 tasks across five areas of routine wet-lab work: protein methods, imaging and cytometry, quantification and assays, nucleic acid methods, and molecular cloning. Tasks range from simple requests, such as reading the molecular weight of a DNA sample in a gel, to detailed assay analysis, but all involve routine work that wet-lab scientists should be able to complete reliably.
科学家利用自己实验中的数据创建了这些任务,并为每个问题配以专家编写的评分标准。每项任务都经过了一位未参与编写该任务的 Ligo 科学家的内部评审、一位在湿实验室工作的博士级科学家的外部评审,以及最终的内部评审。
Scientists created the tasks using data from their own experiments, pairing each question with expert-written grading criteria. Each task underwent an internal review by a Ligo scientist who had not written it, an external review by a PhD-level scientist working in a wet lab, and a final internal review.
智能体返回结构化答案,其中包含所要求的结论、测量结果或建议,并在需要时附上支持性推理。答案根据各项评分标准获得相应分数,使该基准能够区分正确结论与部分正确的分析。大多数任务同时测试多项技能,包括生物学知识、图像及其他数据的解读、错误检测和实验方案理解。
Agents return a structured answer with the requested conclusion, measurement or recommendation and, where required, supporting reasoning. Answers receive credit against individual rubric criteria, allowing the benchmark to distinguish a correct conclusion from a partially correct analysis. Most tasks test several skills together, including biological knowledge, interpretation of images and other data, error detection and protocol understanding.
“唯一任务”对每项任务只计数一次。技能列统计带有各技能标签的任务数。这些类别存在重叠:一项任务可能出现在多列中,因此不应将各技能计数相加来得到任务总数。颜色标识领域;颜色越深表示该领域中测试某一技能的任务占比越大。
“Unique tasks” counts each task once. The skill columns count tasks with each skill tag. These categories overlap: one task can appear in several columns, so the skill counts should not be added to obtain a task total. Color identifies the domain; stronger shading indicates a larger share of that domain’s tasks testing a skill.
输入保留了科学家实际处理的证据形式:凝胶和印迹图像、培养板照片、显微成像序列、测序读段、酶标仪导出数据和实验台操作视频。一项任务可以包含多种数据。参考图表(如分子量标准图和质粒图谱)为实验证据的解读提供支持。
The inputs preserve the forms of evidence scientists work with: gel and blot images, plate photographs, microscopy stacks, sequencing reads, plate-reader exports and videos of bench work. A task can include several kinds of data. Reference sheets, such as ladder charts and plasmid maps, support the interpretation of the experimental evidence.
琼脂糖 DNA 凝胶、SDS-PAGE 凝胶、Western blot
Agarose DNA gels, SDS-PAGE gels, Western blots
实验方案和标准操作程序(SOP)、实验室笔记本和运行记录、手写笔记照片、产品目录、仪器规格、已发表的方法
Protocols and SOPs, lab notebooks and run records, photographed handwritten notes, catalogues, instrument specs, published methods
CSV 和 Excel 导出文件、泳道布局和清单、原始流式细胞术(FCS)文件
CSV and Excel exports, lane layouts and inventories, raw flow cytometry (FCS) files
实验台、凝胶电泳槽、试剂管与培养管、PCR板、试管架、pH试纸、浓缩仪、冰箱、液体处理平台
Benches, gel rigs, reagent and culture tubes, a PCR plate, tube racks, pH strips, a concentrator, a freezer, a liquid-handler deck
原始明场与荧光图像、多通道图像集、Z轴层扫图像、延时摄影视频
Raw brightfield and fluorescence images, multi-channel sets, z-stacks, time-lapse movies
流式细胞仪、显微镜、NanoDrop、酶标仪和天平屏幕的照片;导出的标准曲线、色谱图和图表
Photos of flow cytometer, microscope, NanoDrop, plate reader and balance screens; exported standard curves, chromatograms and plots
原始长读长FASTQ文件、FASTA序列、GenBank图谱
Raw long-read FASTQs, FASTA sequences, GenBank maps
划线接种、接种、梯度稀释、SDS-PAGE电泳槽与培养箱设置、天平称量
Streaking, inoculation, serial dilution, SDS-PAGE tank and incubator setups, weighing on a balance
转化平板、蓝白斑筛选平板、抗生素纸片平板
Transformation plates, blue/white screens, antibiotic-disc plates
分子量标准图表、质粒图谱、pH图表(补充材料)
Ladder charts, plasmid maps, pH charts (supporting material)
包含各类数据的任务数量。类别之间存在重叠;参考表为补充材料。
Number of tasks that include each kind of data. Categories overlap; reference sheets are supporting material.
科学家使用自己实验的数据编写任务,将实验证据与问题及专家编写的评分标准配对。每个任务都经过一位未参与编写的Ligo科学家的内部评审、一位在湿实验室工作的博士级科学家的外部评审,以及最终的内部评审。评审人员检查了提示词、实验证据、评分标准、作者注释以及一次模型作答的评分结果。
Scientists wrote the tasks using data from their own experiments, pairing the experimental evidence with a question and an expert-written grading rubric. Each task went through an internal review by a Ligo scientist who had not written it, an external review by a PhD-level scientist working in a wet lab, and a final internal review. Reviewers checked the prompt, experimental evidence, rubric, author notes and a graded model attempt.
答案根据任务的评分标准进行评分,该标准为各项具体标准分配分数。视任务而定,这些标准评估结论、数值结果、支持性推理或对证据不足的识别。
Answers are scored against the task’s rubric, which assigns credit to individual criteria. Depending on the task, these criteria assess the conclusion, numerical results, supporting reasoning or recognition that the evidence is insufficient.
我们在BioBasicsBench上评估了七个模型:GPT‑5.2、GPT‑5.4、GPT‑5.5、GPT‑5.6 Sol、GPT‑6.1 Sol、GPT‑6 Luna和GPT‑6 Astra。评估涵盖37种模型与推理强度设置,每种设置对100个任务各尝试五次,共产生18,500条结果。
We evaluated seven models on BioBasicsBench: GPT‑5.2, GPT‑5.4, GPT‑5.5, GPT‑5.6 Sol, GPT‑6.1 Sol, GPT‑6 Luna and GPT‑6 Astra. The evaluation covers 37 model and reasoning-effort settings, with five attempts on each of the 100 tasks per setting, for a total of 18,500 results.
我们报告平均奖励:即任务平均得分,以可用分数的百分比表示。误差条显示95%置信区间,通过对整个任务进行重采样计算,并将每个任务的五次尝试保持在一起。
We report mean reward : the average task score, expressed as a percentage of the available credit. Error bars show 95% confidence intervals calculated by resampling whole tasks, keeping the five attempts for each task together.
平均奖励与每任务平均输出 token 数的关系,采用对数刻度展示。每个点代表一种经过测试的推理强度设置;线条按顺序连接这些设置。x 轴每个刻度翻倍。橙色虚线表示 GPT‑5 模型,蓝色实线表示 GPT‑6 模型。浅色须线表示 95% 全任务 bootstrap 置信区间。每种设置均包含全部 100 个任务,每个任务尝试五次。不同模型的推理强度设置有所不同。
Mean reward versus average output tokens per task, shown on a logarithmic scale. Each point represents a tested reasoning-effort setting; lines connect those settings in order. The x-axis doubles at each tick. Dashed orange lines show GPT‑5 models, and solid blue lines show GPT‑6 models. Faint whiskers show 95% whole-task bootstrap confidence intervals. Each setting includes all 100 tasks and five attempts per task. Effort settings differ across models.
即使在低推理强度下,GPT‑6 Astra 也大幅优于 GPT‑5.6 Sol。这些提升表明,更强的原生多模态能力可能是提升日常湿实验室分析表现的关键。
GPT‑6 Astra substantially improves on GPT‑5.6 Sol, even at low reasoning effort. These gains suggest that stronger native multimodal capabilities may be key to improving performance on everyday wet-lab analysis.
Xhigh 是所有七个模型报告的最高推理强度设置。每一行均包含全部 100 个任务,每个任务尝试五次。在可获得的情况下,最高强度(Max-effort)的结果已纳入上图中。
Xhigh is the highest reasoning-effort setting reported for all seven models. Each row includes all 100 tasks and five attempts per task. Max-effort results, where available, are included in the chart above.
科学中的一个常见陷阱是过度解读数据,尤其是在检验假设时出现的偏差性质下。Astra 展现出更强的能力,能够辨别数据所显示范围的界限,而不做出没有依据的结论。
A common trap in science is over-interpreting the data, especially given the nature of bias that occurs when testing a hypothesis. Astra demonstrated a better ability to discern the limit of what the data shows and not draw unwarranted conclusions.
在这个例子中,GPT‑5.6 Sol 根据一种用于检测死细胞的染料信号,将细胞归类为死亡。但检测器也可能接收到第二种染料的光,因此仅凭亮度无法支持这一结论。Astra 识别出了这种模糊性,并呼吁采用更好的对照来分离信号。
In this example, GPT‑5.6 Sol classified cells as dead based on the signal from a dye used to detect dead cells. But the detector could also pick up light from a second dye, so brightness alone could not justify that conclusion. Astra recognized this ambiguity and called for better controls to separate the signals.
三个通道中的相同细胞区域;检测窗口在 525–540 nm 处重叠。共享窗口允许干扰;其干扰量尚未测量。每个通道均以单独的线性强度标尺显示,且在两个区域之间固定;通道之间的亮度无法进行定量比较。
The same cell regions in three channels; the detection windows overlap at 525–540 nm. The shared window permits interference; its amount has not been measured. Each channel is displayed with a separate linear intensity scale, fixed across both regions; brightness cannot be compared quantitatively between channels.
科学研究具有高度多模态性,需要持续的视觉解读和决策。Astra 在处理以照片和视频形式提供的多模态数据,以及来自测序、板式读取器检测、显微镜和流式细胞术的原始输出方面,表现出显著改善。
Scientific research is highly multimodal, requiring constant visual interpretation and decision making. Astra displayed a significant improvement at handling multimodal data which was given in the form of photos and videos, as well as raw outputs from sequencing, plate-reader assays, microscopy and flow cytometry.
在最基本的层面上,这种提升体现在 GPT‑6 Astra 能够从实验过程中拍摄的图像中捕捉到更细微的细节,从而得出更准确的结论,如下例所示。该任务要求智能体从一项 DNA 克隆实验中得出结论,而在这类实验中对照组至关重要。GPT‑5.6 Sol 在阴性对照平板上没有看到菌落,并基于这一观察得出结论。GPT‑6 Astra 注意到该平板标注了错误的抗生素,并正确地将其判定为不可靠的对照而予以排除。
At the most basic level, this improvement was noticeable through GPT‑6 Astra’s ability to pick up on finer detail from images taken during experiments and therefore draw more accurate conclusions as shown in this example. This task asked agents to draw conclusions from a DNA cloning experiment, where controls are essential. GPT‑5.6 Sol saw no colonies on the negative control plate and based its conclusions on that observation. GPT‑6 Astra noticed that the plate was labeled with the wrong antibiotic and correctly rejected it as a reliable control.
原始基准照片,边缘标签已圈出并放大。“LB Kan50”标识的是卡那霉素,一种与实验中所用氨苄青霉素不同的抗生素。
The original benchmark photograph, with the rim label circled and enlarged. “LB Kan50” identifies kanamycin, a different antibiotic from the ampicillin used in the experiment.
科学家必须能够在分析数据的同时,将隐性的生物学知识和实验背景记在心中,才能正确解读数据所显示的内容。Astra 在保持这种背景并将其贯穿于整个分析过程方面表现出了更强的能力。
Scientists must be able to hold tacit biological knowledge and experimental context in mind whilst analysing data in order to correctly interpret what it shows. Astra demonstrated an improved ability to maintain this context and apply it throughout its analysis.
其中一项任务展示了一系列显微镜图像中细胞进入和离开焦平面的过程。GPT‑5.6 Sol 试图为细胞看似消失的现象寻找生物学解释,而 GPT‑6 Astra 则正确识别出这是一个 z 轴堆栈:即在不同深度拍摄的一系列图像。
One task showed cells coming into and out of focus in a series of microscope images. While GPT‑5.6 Sol looked for a biological explanation for the cells’ apparent disappearance, GPT‑6 Astra correctly recognized a z-stack: a series of images taken at different depths.
原始录像中的六帧画面。虚线框标出了显微镜在深度扫描过程中经过的同一位置。时间指所提供视频中的播放位置。
Six frames from the original recording. Dashed boxes mark the same location as the microscope scans through depth. Times refer to playback position in the supplied video.
更高的基准分数尚不意味着模型能在实验室中做出可靠判断。这些 Astra 的示例表明,假设、预期答案和所提供的标签如何可能压过证据,以及一个正确的中间观察结果如何可能未能引导最终决策。
Higher benchmark scores do not yet mean models can make reliable judgments in the lab. These Astra examples show how assumptions, expected answers and supplied labels can override the evidence, and how a correct intermediate observation can fail to guide the final decision.
Astra 让一个熟悉的假设压过了实验对照所支持的解读。它能够区分两组菌落条带,但假定较大的 PCR 产物就能判定克隆成功。基于这一条件,它提出第 4、6、7 和 8 泳道;而参考标准的对照比较则选择第 5、9 和 10 泳道。
Astra lets a familiar assumption override the interpretation supported by the experimental controls. It can distinguish the two groups of colony bands, but assumes that a larger PCR product would identify successful cloning. On that condition it proposes lanes 4, 6, 7 and 8 ; the reference’s control comparison instead selects lanes 5, 9 and 10 .
参考标准选择菌落 5、9 和 10;Astra 则提出 4、6、7 和 8。
The reference selects colonies 5, 9 and 10 ; Astra proposes 4, 6, 7 and 8 .
1:marker · 2:克隆混合物 · 3:原始质粒 · 4–10:菌落样本
1: marker · 2: cloning mixture · 3: original plasmid · 4–10: colony samples
第 3 泳道仅包含原始质粒 PCR。其条带提供了旧质粒的参考位置。
Lane 3 contains only the original plasmid PCR. Its band provides the old-plasmid reference position.
在参考解读中,第 2 泳道同时包含两种模式:不完整的组装使旧模板/骨架与新产物并存。
In the reference interpretation, lane 2 contains both patterns : incomplete assembly leaves old template/backbone alongside the new product.
所得菌落可能携带旧质粒或新质粒。将其条带与这些参考模式进行比较。
The resulting colonies can carry either old or new plasmid. Compare their bands with these reference patterns.
Astra 的选择:4、6、7 和 8。Astra 提名这一组,暗示较大的 PCR 产物代表预期的构建体。
Astra’s selection: 4, 6, 7 and 8. Astra nominates this group suggesting the larger PCR product represents the intended construct.
视觉分组是正确的,但附加到这些组上的实验身份相对于参考是颠倒的。因此,Astra 从菌落 PCR 结果中选择了错误的菌落,这将导致下游纯化出错误的质粒。
The visual grouping is correct but the experimental identities attached to those groups are reversed relative to the reference. Astra therefore selects the wrong colonies from the colony PCR results which would result in the down-stream purification of the incorrect plasmid.
Astra 轻视与其偏好解读相矛盾的观察结果。它得出结论称,液泡(细胞内的区室)通常比周围细胞更暗,尽管在同一图像中有些液泡显得更亮。两种外观都很重要:改变显微镜的焦距可以反转对比度,因此较暗的示例并不能确立一般规律。
Astra discounts observations that contradict its preferred interpretation. It concludes that vacuoles, compartments inside cells, are generally darker than the surrounding cell, even though some appear lighter in the same image. Both appearances matter: changing the microscope’s focus can reverse the contrast, so the darker examples do not establish a general rule.
Astra 关于较暗液泡的概括忽略了同一视野中可见的较亮液泡。
Astra’s darker-vacuole generalisation omits the lighter vacuoles visible in the same field.
一些细胞具有相反的对比度。两种外观都会出现,因为不同的焦深可以反转对比度。
Some cells have an opposite contrast. Both appearances occur because different focal depths can reverse the contrast.
Astra 检查了多个区域,甚至评论说对比度随焦距变化。然后它更重视其称为对焦更好的细胞,并在最终答案中仅保留这些细胞的较暗液泡描述。矛盾的较亮区域已被检查,但未在结论中考虑。
Astra inspects several regions and even comments that contrast varies with focus. It then gives greater weight to the cells it calls better focused and retains only their darker-vacuole description in the final answer. The contradictory lighter regions have been inspected but are not considered in the conclusion.
Astra 的计数标记不能可靠地对应单个菌落:它未能分辨邻近的菌落,遗漏了可见菌落,并标记了空琼脂。该培养皿上的净结果是相对于基准参考高估了约 12%。
Astra’s counting marks do not reliably correspond to individual colonies: it fails to resolve close neighbours, misses visible colonies and marks empty agar. The net result on this plate is an overcount of approximately 12% relative to the benchmark reference.
A:相邻菌落之间有一个计数标记。B:两个可见菌落未作标记。C:空琼脂被计为一个菌落。红圈表示 Astra 的计数位置。黑色箭头为编辑指引。
A: one counting mark between neighbouring colonies. B: two visible colonies left unmarked. C: empty agar counted as a colony. Red circles indicate Astra’s counting positions. Black arrows are editorial guides.
菌落计数不准确会直接影响对 DNA 导入细胞效率的估计。在接种体积和稀释度固定的情况下,计数偏高会以相同比例高估该效率。
An inaccurate colony count directly affects estimates of how efficiently DNA was introduced into cells. With the plated volume and dilution held fixed, an overcount inflates that estimate by the same proportion.
加速生物学研究需要把日常工作做对。BioBasicsBench 将这些工作设为改进目标:解读原始实验数据、检查对照,以及识别结论缺乏支持的情况。在这些任务上取得进展,有助于科学家减少排查故障的时间,把更多时间用于决定接下来开展哪些实验。追踪这些能力也将帮助我们理解其对生物安全和生物安保的影响。
Accelerating biological research requires getting the everyday work right. BioBasicsBench makes that work a target for improvement: interpreting raw experimental data, checking controls and recognizing when a conclusion is not supported. Progress on these tasks could help scientists spend less time troubleshooting and more time deciding which experiments to pursue next. Tracking these capabilities will also help us understand their implications for biosafety and biosecurity.